After a study on the characteristic of ECG data, we propose here in this paper a lossless compression method of ECG data, which is based on JPEG2000. It integrates both 1D and 2D compression. The method has been verified through all forty-eight records in MIT-BIH Arrhythmia database. And the result shows that the method has a better compression rate and a good computational efficiency.