<p><b>OBJECTIVE</b>To establish an ion chromatography (IC) method for determination of ammonia in air of workplace.</p><p><b>METHODS</b>Ammonia in workplace air was collected in silica gel tube, desorbed with 10 mmol/L methanesulfonic acid by ultrasonic for 10 min, determined by IC.</p><p><b>RESULTS</b>The linearity range was 0.02-1.00 microg/ml. The linear equation was Y = 12041X-187 (r = 0.9997). The limit of quantification was 0.13 mg/m3 (the air volume was 1.5 L). Collection efficiency was 100%. Extraction efficiency was 99%. The relative standard deviation was 4.2%-6.3%. The penetration capacity was more than 264 microg. Sample could be stored for 14 days at least by ambient storage.</p><p><b>CONCLUSION</b>This method is convenient, applicable and sensitive, suitable to determinate ammonia in air of workplace.</p>
Subject(s)
Full text: Available Database: WPRIM (Western Pacific) Main subject: Specimen Handling / Chromatography, Gas / Workplace / Air Pollutants, Occupational / Ammonia / Methods Language: Chinese Journal: Chinese Journal of Industrial Hygiene and Occupational Diseases Year: 2012 Document type: Article