Detecting 2-butoxy ethanol in the air of workplaces by gas chromatography / 中华劳动卫生职业病杂志
Chinese Journal of Industrial Hygiene and Occupational Diseases
; (12): 389-390, 2012.
Article
in Chinese
| WPRIM (Western Pacific)
| ID: wpr-324255
Responsible library:
WPRO
ABSTRACT
<p><b>OBJECTIVE</b>To establish a gas chromatographic method for detecting 2-butoxy ethanol in the air of workplaces.</p><p><b>METHODS</b>After the air samples were collected with activated carbon tubes and desorbed with methylene chloride/methanol, the target toxicant was separated with FFAP capillary columns and detected with flame ionization detector, qualified by retention time and quantified by peak area.</p><p><b>RESULTS</b>The linear range of 2-butoxy ethanol in air of workplace was 56.3 ∼ 901.0 µg/ml, the correlation coefficient was 09999. The limit of detection was 2.0 µg/ml. The limit of quantity was 5.0 µg/ml. The minimal detecting concentration was 0.27 mg/m(3) in the condition of 7.5L sampling volume and 1ml desorbed volume. Relative standard deviation was 3.04% ∼ 7.93% and the recovery was 92.7% ∼ 95.5%.</p><p><b>CONCLUSION</b>In present study the detecting method with high sensitivity, precision and accuracy can be used to determine 2-butoxy ethanol in the air of workplaces.</p>
Full text:
Available
Database:
WPRIM (Western Pacific)
Main subject:
Chromatography, Gas
/
Workplace
/
Air Pollutants, Occupational
/
Ethylene Glycols
/
Methods
Language:
Chinese
Journal:
Chinese Journal of Industrial Hygiene and Occupational Diseases
Year:
2012
Document type:
Article