Ruptured Dacron Prosthesis by Blunt Trauma 8 Years after Implantation for Axillo-femoral Bypass / 日本心臓血管外科学会雑誌
Article in Japanese | WPRIM (Western Pacific) | ID: wpr-365804
Responsible library: WPRO
ABSTRACT
A case of a 77-year-old man is reported, who developed late rupture of the knitted Darcon velour graft by blunt trauma 8 years after implantation for axillo-femoral bypass. Dacron fiber deterioration, which led the graft to fragility, might have played a main role in the clinical setting. This case clearly emphasizes that with its possibility to be deteriorated life-long care and follow up should be taken for the patients who undergo arterial reconstructive surgery using Dacron prostheses.

Full text: Available Database: WPRIM (Western Pacific) Language: Japanese Journal: Japanese Journal of Cardiovascular Surgery Year: 1992 Document type: Article