ABSTRACT

Objective:

To compare the dissolution of domestic terazosin hydrochloride tablets and capsules to provide reference for clinical use.

Methods:

The dissolution of the products from different manufacturers was investigated respectively in 4 kinds of mediapH 1. 0 hydrochloric acid solution,pH 4. 5 phosphate buffer solution,pH 6. 8 phosphate buffer solution and water. The dissolution tests were carried out by a paddle method at the stirring speed of 50 r·min-1 and an HPLC method was used to determine the dissolution rate. The dissolution behavior of the samples from different manufacturers was compared by a similar factor method.

Results:

The do-mestic tablets showed higher similarity with the reference formula, and the dissolution behavior of the capsules had significant differ-ence.

Conclusion:

The calculation method for the specification in some manufacturers is different from that of the reference prepara-tion, which leads to the difference between the testing preparation and the reference preparation, and should be paid attention in clini-cal use.

Full text: Available Database: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacist Year: 2015 Document type: Article