Your browser doesn't support javascript.
loading
Conical telescopic crown denture versus traditional removable denture for restoration of an isolated abutment tooth:a three-dimensional finite element analysis / 中国组织工程研究
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-487332
Responsible library: WPRO
ABSTRACT

BACKGROUND:

The conical telescopic crown denture has a better long-term effect on dentition defects of few remaining teeth than the traditional removable denture. However, there are few studies to analyze the application of these two kinds of repair methods using the finite element method.

OBJECTIVE:

To compare the stress distribution of the isolated abutment tooth repaired using the conical telescopic crown denture and traditional removable denture.

METHODS:

Two-dimensional images of the mandible and dentition in healthy adults were scanned by CT. Three-dimensional finite element models of conical telescopic crown denture and traditional removable denture were established in the mandible only with the bilateral canines. Under the same vertical and oblique loadings, the maximum equivalent stress of the abutment, periodontal membrane or edentulous alveolar ridge was compared between two repair methods. RESULTS AND

CONCLUSION:

Under the vertical and oblique loadings, the total stress of abutment and periodontal membrane in the traditional removable denture was higher than that in the conical telescopic crown denture and the stress in the corresponding ring was concentrated obviously; the total stress of edentulous alveolar ridge in the conical telescopic crown denture was slightly larger than that in the traditional removable denture, but the stress was wel -distributed and concentrated in a smal area. Under the oblique loading, the total stress of abutment, periodontal membrane and edentulous alveolar ridge was higher than that under the vertical loading in these two dentures, and the stress was concentrated in the periodontal membrane of lingual neck, but the total stress in the traditional removable denture was larger, with a wider concentration range. These findings indicate that the stress on the supporting tissue of conical telescopic crown denture is more evenly distributed within a smal er range than that of traditional removable denture, and the former is more fit for the health of abutment, periodontal tissues and edentulous alveolar ridge.
Full text: Available Database: WPRIM (Western Pacific) Type of study: Prognostic study Language: Chinese Journal: Chinese Journal of Tissue Engineering Research Year: 2016 Document type: Article
Full text: Available Database: WPRIM (Western Pacific) Type of study: Prognostic study Language: Chinese Journal: Chinese Journal of Tissue Engineering Research Year: 2016 Document type: Article
...