ABSTRACT

OBJECTIVE:

To establish a method for the content determination of baicalin in Yangyin mixture.

METHODS:

HPLC was performed on the column of SunFire C18 with mobile phase of methnol-water-phosphoric acid(43∶57∶0.2,V/V/V)at a flow rate of 1.0 ml/min,the detection wavelength was 280 nm, column temperature was 30 ℃,and the volume injection was 10 μl.

RESULTS:

The linear range of baicalin was 0.055 75-1.115 μg(r=0.999 9);RSDs of precision,stability and reproducibility test were lower than 2%;recovery was 95.39%-98.44%(RSD=1.19%,n=6).

CONCLUSIONS:

The method is simple,rapid and accurate,and suitable for the content determination of baicalin in Yangyin mixture.

Full text: Available Database: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2016 Document type: Article