Determination of Valsartan Concentration in Human Plasma With HPLC / 中国药房
China Pharmacy ; (12)2001.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-517863
Responsible library: WPRO
ABSTRACT

OBJECTIVE:

To determine the valsartan concentration in human plasma

METHODS:

The plasma sample was extracted with a liquid-solid method and determined with HPLC,stationary phase was Hypensil ODS C18(4 6nm?200nm,5?m),mobile phase consisted of acetonitrile and 0 01mol/L KH2PO4 buffer(pH 2 8)(50∶50) The flow rate was 1 5ml/min Detection was performed with fluorescence detector at ?ex 265nm,?em 378nm

RESULTS:

The retention time of valsartan was about 5 4 minutes,and the linear range of quantity was 0 05~5?g/ml The recoveries of methodology were more than 90%(n=5) Inter-day and intra-day RSD were less then 10%(n=5)

CONCLUSION:

This method is rapid and accurate It can be applied to determining the plasma valsartan concentration and studying on pharmacokinetics

Full text: Available Database: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2001 Document type: Article
Full text: Available Database: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2001 Document type: Article
...