ABSTRACT
Objective To evaluate the cause which leads to the allelic dropouts at D8S1179 locus while performing paternity testing with the AmpFlSTR Profiler Plus kit. Methods A singleplex amplification system for D8S1179 locus (GenBank Accession No. G08710) was used to verify the typing results by using the AmpFlSTR?Profiler plus kit. Dropout alleles were then sequenced. Results G to A transition was identified at the position of the 147th base of the GenBank sequence. The frequency of the G to A transition among the Chinese population was 0.50 X 10"2 (10 out of 2013 unrelated individuals). Conclusion The G to A transition may be located at the binding site of one of the primers of the AmpFlSTR?Profiler Plus kit. It is suggested that the G to A transition might be the cause of the allelic dropout at the D8S1179 locus.

Full text: Available Database: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Forensic Medicine Year: 1986 Document type: Article