Study of Quality Control Method for Compound Weilining Nose Drops / 中国药房
China Pharmacy
; (12)2001.
Article
in Chinese
| WPRIM (Western Pacific)
| ID: wpr-521750
Responsible library:
WPRO
ABSTRACT
OBJECTIVE:
To establish the quality control method for compound Weilining nose drops.METHODS:
First order derivation spectrophotometry was used to determine the content of Weilining in nose drops at wavelength224.7nm.RESULTS:
A linearity of concentration(C)and amplitude(D)of Weilining solution was found in range of5~20?g/ml with a regression equation of C=—1.3438+520.78D;(r=0.9998),The average recovery rate was100.35%(n=9),RSD=0.87%.CONCLUSION:
The Weilining nose drops is simple in preparation and stable in quality,and this method can be used for quality control of the preparation.
Full text:
Available
Database:
WPRIM (Western Pacific)
Language:
Chinese
Journal:
China Pharmacy
Year:
2001
Document type:
Article