Determination of Camphor in Compound Menthol Nose Drop by RP-HPLC / 中国药房
China Pharmacy ; (12)2001.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-525108
Responsible library: WPRO
ABSTRACT

OBJECTIVE:

To determine camphor in compound menthol nose drop by RP-HPLC.

METHODS:

Waters No-va-pak C 18 was taken as the chromatographic column,the mobile phase was composed of chloroform-methanol-water(14∶52∶30)with a flow speed at1.0ml/min and detection wavelength at289nm,the column temperature was35℃.

RESULTS:

The linear range for camphor was0.8~5.6?g/ml(r=0.9998)and the average recovery rate was99.4%(RSD=0.7%).

CONCLUSION:

The method is specific,convenient and accurate,which can be used for the quality control of the preparation.

Full text: Available Database: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2001 Document type: Article