Determination of Acipimox in Human Serum by HPLC / 中国药房
China Pharmacy
; (12)2005.
Article
in Chinese
| WPRIM (Western Pacific)
| ID: wpr-526039
Responsible library:
WPRO
ABSTRACT
OBJECTIVE:
To establish HPLC method for the determination of acipimox in human serum.METHODS:
The determination was performed on C18 column under room temperature, the mobile phase consisted of methanol -water(1585) with a flow rate of 0.8ml/ min and detection wavelength of 260nm, the quantitation was conducted by external reference method,the serum was subjected to protein sediment by methanol,the supernate fluid obtained thereafter was undergone sample injection.RESULTS:
The linear range of acipimox was 1.0-16.0?g/ml (r = 0.9 987),the minimum detection concentration was 0.5?g/ ml; the average recovery of method was 96.05% .CONCLUSION:
This method is simple, fast, sensitive and accurate, and which can be applied for blood concentration monitoring and pharmacokinetic study of acipimox.
Full text:
Available
Database:
WPRIM (Western Pacific)
Language:
Chinese
Journal:
China Pharmacy
Year:
2005
Document type:
Article