GC determination of camphor and eucalyptol in Shidi Water / 中成药
Chinese Traditional Patent Medicine
; (12)1992.
Article
in Chinese
| WPRIM (Western Pacific)
| ID: wpr-578377
Responsible library:
WPRO
ABSTRACT
AIM:
To establish a method for determing camphor and eucalyptol in Shidi Water(Camphor,Rhizoma Zingiberis,Fructus Foeniculi,Cortex).METHODS:
The chromatographic condition,DB-WAX capillary column(30 m?0.53 mm,1 ?m).The column temperature programming was from 65 ?C to 155 ?C(at rate of 6 ?C/min).FID Detection.The temperatrue was at 230 ?C.RESULTS:
The linear range of camphor was within 0.18 mg/mL-5.78 mg/mL(r=1.000 0,n=6).The average recovery was 98.05%,RSD=0.94%.The linear range of eucalyptol was within 0.06 mg/mL-1.92 mg/ml(r=(0.999 7),n=6).The average recovery was 98.99%,RSD=1.31%.CONCLUSION:
This method can be used for quality control of Shidi Water
Full text:
Available
Database:
WPRIM (Western Pacific)
Language:
Chinese
Journal:
Chinese Traditional Patent Medicine
Year:
1992
Document type:
Article