Clinical application of fiberoptic ductoscopy in 800 cases / 中国微创外科杂志
Article in Zh | WPRIM | ID: wpr-583969
Responsible library: WPRO
ABSTRACT
Objective To assess the value of fiberoptic ductoscopy (FDS) in the diagnosis of nipple discharge.Methods Clinical records of 800 patients with nipple discharge undergoing FDS from October 1998 to July 2003 were retrospectively reviewed. Results Diagnoses established by FDS were pathologically confirmed in 92 2% of patients with papilloma (202/219), in 86 7% of patients with papillomatosis (13/15), and in 95 2% of patients with breast cancer (40/42). The total diagnostic accordance rate was 92 0% (266/289). Conclusions FDS in the diagnosis of nipple discharge is sensitive and of great clinical significance.
Key words
Full text: 1 Database: WPRIM Language: Zh Journal: Chinese Journal of Minimally Invasive Surgery Year: 2001 Document type: Article