Determination of hypoxanthine and xanthine in Syngnathus by HPLC / 中国海洋药物
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-586439
Responsible library: WPRO
ABSTRACT
Objective To establish a HPLC method for determination of hypoxanthine and xanthine in Syngnathus.Methods A Lichrosper C_(18) Column was used.The mobile phase was methanol-0.1%HAc.Walvelength was 254nm.Results The linear range of hypoxanthine was within 5.91~94.56?g?mL~(-1),r=0.9999,sample recovery rate was 99.22%,RSD=(1.25)%.The linear range of Xanthine was within 2.04~32.64?g?mL~(-1),r=0.9998,sample recovery rate was 98.05%,RSD=1.21%.Conclusion This method has good repeatability and flexibility.It can be used for quality control in production of Syngnathus.

Full text: Available Database: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Marine Drugs Year: 1994 Document type: Article