Your browser doesn't support javascript.
loading
Influence of Various Packaging Methods and Controlling Method Toward Hidden Wet Pack after Steam Sterilization / 中华医院感染学杂志
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-592141
Responsible library: WPRO
ABSTRACT
OBJECTIVE To study the influence of various packing methods and controlling method toward the hidden wet pack after steam sterilization to ensure the sterilization quality and hygiene safety.METHODS The medical equipment was packed with three types of methods,then unloaded from the steam autoclave after being cooled at different time to observe their heating speed respectively.To choose two types of cotton fabric packaging methods,prolong the heating time,and cool in the steam autoclave for 30 minutes,then observe the heating speed of the inside pack and the dry qualification status after 12 hours respectively.RESULTS The heating speed was the fastest with the medical crinkly paper method;the heating speed of the inside pack didn't have any improvement after prolonging the heating time;the dry qualification rate had distinct difference between the two types of cotton fabric methods after 12 hours(P

Full text: Available Database: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Nosocomiology Year: 2006 Document type: Article