ABSTRACT
AlM To investigate the clinical effect of preserved amniotic membrane transplantation in the treatment to conjunctival rupture, dehiscence and socket contracture after hydroxyapatite ( HA) orbital implantation.

METHODS:

ln 16 cases of conjunctival rupture and socket contracture after HA orbital implantation, conjunctival tension was release by operation and preserved amniotic membrane was transplanted on conjunctival scleral exposure area.

RESULTS:

ln all cases, conjunctiva healing, completely cover the sclera and conjunctiva socket recover ideal depth after operation in 15 cases, 1 case was fail. CONCLUSlON Preserved amniotic membrane transplantation is an effective method to treat conjunctival dehiscence and keeping the ideal conjunctival socket depth after orbital implantation.

Full text: Available Database: WPRIM (Western Pacific) Language: Chinese Journal: International Eye Science Year: 2014 Document type: Article