Determination of Feruloyltyramine in Pothi Chinensis Herba by HPLC / 中国药师
China Pharmacist
; (12): 1790-1792, 2015.
Article
in Zh
| WPRIM
| ID: wpr-670057
Responsible library:
WPRO
ABSTRACT
Objective: To develop an HPLC method for determining feruloyltyramine in Pothi chinensis herba. Methods: The HPLC determination was performed on a Thermo ODS-2 Hypersil column(250 mm × 4. 6 mm, 5 μm) with isocratic elution of metha-nol-0. 4% phosphoric (35:65) as the mobile phase. The flow rate was 1. 0 ml·min-1 . The column temperature was at 25℃, and the detection wavelength was set at 318 nm. Results: Feruloyltyramine showed good linearity,and the recovery was 99. 40% with RSD of 1. 44% (n =9). Conclusion: The method is quick, simple and reproducible, which can be used to control the quality of Pothi chinensis herba.
Full text:
1
Database:
WPRIM
Language:
Zh
Journal:
China Pharmacist
Year:
2015
Document type:
Article