Your browser doesn't support javascript.
loading
On the effects of the characteristics of the titanium oxide to the osteoblast cell culture / 대한치과보철학회지
Article in English | WPRIM (Western Pacific) | ID: wpr-77405
Responsible library: WPRO
ABSTRACT
STATEMENT of

PROBLEM:

Confusion about the relationship of surface characteristics of implant to osteoblast cell attachment.

PURPOSE:

This study attempted to bone cell attachment to the implant surface which was modified by heat. MATERIAL AND

METHODS:

Commercially pure titanium grade 2, 4x4mm sheet 40 pieces were treated for 10 minutes with ultrasonic cleaner with methylethyl ketone, ethanol, deionized distilled water, and half of the specimen 20 pieces were heat treated in 980degreesC for 15 minutes. All 40 specimens were autoclaves. Total 6 dishes were prepared, 3 dishes were for control group, and the other 3 dishes were for heat treatment. In fourth day, cell account was done. CONCULSION The change of surface characterization by heat treatment could affect the cell attachment in the early stage however, the change of surface characterization would not be prolonged.
Subject(s)
Full text: Available Database: WPRIM (Western Pacific) Main subject: Osteoblasts / Titanium / Ultrasonics / Water / Cell Culture Techniques / Ethanol / Hot Temperature Language: English Journal: The Journal of Korean Academy of Prosthodontics Year: 2000 Document type: Article
Full text: Available Database: WPRIM (Western Pacific) Main subject: Osteoblasts / Titanium / Ultrasonics / Water / Cell Culture Techniques / Ethanol / Hot Temperature Language: English Journal: The Journal of Korean Academy of Prosthodontics Year: 2000 Document type: Article
...