Your browser doesn't support javascript.
loading
Impact of aortic root morphology on the implantation depth of aortic valve prosthesis during trans-catheter aortic valve replacement in patients with native bicuspid aortic valve stenosis / 中华心血管病杂志
Zhonghua xinxueguanbing zazhi ; (12): 629-634, 2018.
Article in Zh | WPRIM | ID: wpr-807119
Responsible library: WPRO
ABSTRACT
Objective@#To investigate the impact of aortic root morphology on the implantation depth of aortic valve prosthesis during trans-catheter aortic valve replacement (TAVR) in bicuspid aortic valve patients.@*Methods@#Clinical data of 40 patients with native bicuspid aortic valve stenosis who underwent TAVR using the self-expandable prosthesis (the Venus A-valve) from 2014 to 2017 in Fuwai Hospital was retrospectively analyzed. The patients were divided into non-deep implantation group (implant depth ≤10 mm by instant angiogram after implantation,29 cases) and deep implantation group (implant depth> 10 mm by instant angiogram after implantation,11 cases).Pre-procedural aortic root characteristics (e.g. calcification, angle and dimensions) were assessed by CT. The impact of aortic root morphology on the implantation depth and clinical outcomes were also evaluated.@*Results@#The age was (75.1±5.9) years with equal representation from the raphe-type and non-raphe type (52.5%(21/40) and 47.5%(19/40)).The bigger aorta angle ((56.5±4.5)° vs. (47.4±9.4)°, P=0.004),more frequent mild-calcification (HU850, <200 mm3) or severe-calcification(HU850, >1 000 mm3) of aortic leaflets (7/11 vs. 4/29, P=0.006), as well as higher ratio of left ventricular outflow tract perimeter to annulus perimeter ((109.2±7.5)% vs. (101.5±6.5)%, P=0.004) were found in the deep implantation group compared to the non-deep implantation group. The new in-hospital onset of bundle-branchheart-block or atrioventricular block conduction disturbance rate was higher in the deep implantation group than in the non-deep implantation group (6/11 vs. 2/29, P=0.030).Left ventricular ejection fraction was similar between deep implantation group and non-deep implantation group at baseline((49.9±8.9)% vs. (55.8±10.4)%, P=0.117), and was significantly lower in the deep implantation group than in the non-deep implantation group at 30 days after implantation ((51.6±12.8)% vs. (60.9±8.1)%, P=0.020).@*Conclusion@#Aortic root morphology of bicuspid aortic valve patients is associated with implantation depth of the prosthesis during TAVR, which affects the conduction system and left ventricular function during and post TAVR.
Key words
Full text: 1 Database: WPRIM Type of study: Prognostic_studies Language: Zh Journal: Zhonghua xinxueguanbing zazhi Year: 2018 Document type: Article
Full text: 1 Database: WPRIM Type of study: Prognostic_studies Language: Zh Journal: Zhonghua xinxueguanbing zazhi Year: 2018 Document type: Article