Determination of the content of rocuronium bromide by HPLC / 国际药学研究杂志
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-845962
Responsible library: WPRO
ABSTRACT

Objective:

To establish a HPLC method to determinate the content of rocuronium bromide.

Methods:

NH2-bonding silica gel was used as the stationary phase. The mobile phase consisted of 0.04 mol/L tetramethyl ammonium hydroxide (pH adjusted to 7.4 by phosphoric acid) and acetonitrile (1090). The column temperature was 35°C. The detection wavelength was 207 nm.

Results:

The relation between concentration and peak area was linear in the range of 0.1251-2.0065 mg/ml with r2 of 0.9999. The average recovery rate was 99.9% with RSD of 0.1%.

Conclusion:

This method is exclusive, sensitive and is reliable for the determination of rocuronium bromide.

Full text: Available Database: WPRIM (Western Pacific) Language: Chinese Journal: Journal of International Pharmaceutical Research Year: 2010 Document type: Article