Initial report of extraperitoneal pedicle dissection in deep inferior epigastric perforator flap breast reconstruction using the da Vinci SP
Archives of Plastic Surgery
; : 34-38, 2022.
Article
in English
| WPRIM (Western Pacific)
| ID: wpr-913617
Responsible library:
WPRO
ABSTRACT
The deep inferior epigastric perforator (DIEP) flap has been widely used for autologous breast reconstruction after mastectomy. In the conventional surgical method, a long incision is needed at the anterior fascia of the rectus abdominis muscle to obtain sufficient pedicle length; this may increase the risk of incisional hernia. To shorten the incision, several trials have investigated the use of endoscopic/robotic devices for pedicle harvest; however, making multiple additional incisions for port insertion and operating in the intraperitoneal field were inevitable. Here, we describe the first case, in which a DIEP free flap was successfully made using the da Vinci SP model. Our findings can help surgeons perform operations in smaller fields with a single port in the extraperitoneal space. Moreover, this method is expected to lead to fewer donor-related complications and faster healing.
Full text:
Available
Database:
WPRIM (Western Pacific)
Type of study:
Prognostic study
Language:
English
Journal:
Archives of Plastic Surgery
Year:
2022
Document type: