Modification of the working length after rotary instrumentation. A comparative study of four systems
Med. oral patol. oral cir. bucal (Internet)
; 14(3): e153-157, mar. 2009. ilus, tab
Artículo
en Inglés
| IBECS
| ID: ibc-136128
Biblioteca responsable:
ES1.1
Ubicación: BNCS
ABSTRACT
Objective:
To determine variation in post-instrumentation working length and root area in the following rotary systems ProTaper, RaCe, Mtwo and K3. Studydesign:
A sample of 40 resin blocks with double curvature (at 14 and 16 mm) and a 33o angle was used. Working length was verified with a digital measure using a number 10 K file. The specific sequence for each rotary system was followed. The canal was measured between each file, and the variation noted to determine which file showed the greatest variation within a same system and the different systems were compared. 1.5 X pre and post-instrumentation microscopic photographs were taken and measurements of the area were taken with an im- age analysis programme.Results:
The area was found to increase by the following amounts ProTaper 21.85 mm2; Mtwo 20.16 mm2; K3 17.24 mm2 and RaCe 16.09 mm2. The differences in variation of the working length were ProTaper 0.81 mm; Mtwo 1.07 mm; K3 0.31 mm and RaCe 0.81 mmConclusions:
The values for the variation in working length are clinically not very significant. All the rotary systems analysed showed a tendency to straighten the canal and eliminate the apical curvature, and the ProTaper system was found to produce the greatest modification to the canal area and structure (AU)
Buscar en Google
Colección:
Bases de datos nacionales
/
España
Base de datos:
IBECS
Asunto principal:
Preparación del Conducto Radicular
Límite:
Humanos
Idioma:
Inglés
Revista:
Med. oral patol. oral cir. bucal (Internet)
Año:
2009
Tipo del documento:
Artículo
Institución/País de afiliación:
Universidad CEU-Cardenal Herrera/Spain
/
Universitat de València/Spain