Estudo de calibração do Questionário de Frequência Alimentar para Adolescentes (QFAA) / Calibration study of the Food Frequency Questionnaire for Adolescents (AFFQ)
Ciênc. Saúde Colet. (Impr.)
; Ciênc. Saúde Colet. (Impr.);16(4): 2335-2343, abr. 2011. tab
Article
en Pt
| LILACS
| ID: lil-586582
Biblioteca responsable:
BR1.1
RESUMO
Para determinar fatores de calibração do Questionário de Frequência Alimentar para Adolescentes (QFAA), participaram do estudo 74 adolescentes de Piracicaba (SP), com idades entre 10 e 14 anos. Dados de consumo alimentar foram levantados por meio de um QFAA e dois recordatórios de 24 horas ajustados pela energia. Foram realizadas análises descritivas, análise de variância com um fator de classificação, coeficientes de correlação de Pearson e regressão linear. A média dos dois recordatórios foi utilizada como referência para calibrar os dados. Os coeficientes de calibração variaram de -0,07 (ferro) a 0,40 (vitamina C), mostrando substancial erro no método de inquérito dietético testado, mas sendo semelhantes aos observados na literatura. Devido ao fato de se apresentarem baixos, indicam a necessidade de reformulação do instrumento para alguns nutrientes, sendo desaconselhada sua aplicação para corrigir informações de ferro e retinol. A metodologia utilizada é capaz de considerar nas análises os erros de mensuração quando suas pressuposições são respeitadas, uma vez que violações desses pressupostos podem levar ao surgimento de outros erros de difícil predição.
ABSTRACT
In order to establish calibration factors of the Adolescent Food Frequency Questionnaire (AFFQ), 74 boys and girls from Piracicaba (SP, Brazil) with ages ranging from 10 to 14 took part in the study. Dietary intake (assessed by the food frequency questionnaire and 24-hour recall) was assessed and adjusted for energy intake. Descriptive statistics, variance analysis using one classification factor, Pearson's correlation coefficients and linear regression were performed. The average of two 24-hour recalls was used as a reference for calibration of data. Calibration coefficients (λ) ranged from -0.07 (iron) to 0.40 (vitamin C) revealing substantial error in the dietary method tested, albeit similar to those observed in the literature. As these coefficients were low, they indicate the need for reformulating the instrument regarding some nutrients, though application was not considered advisable for correcting information on iron and retinol. The methodology used to calibrate dietary data can consider measurement error in the assessment when its assumptions are respected, since violations of these assumptions may lead to other errors that are difficult to predict.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
LILACS
Asunto principal:
Encuestas y Cuestionarios
/
Conducta Alimentaria
Tipo de estudio:
Prognostic_studies
/
Screening_studies
Límite:
Adolescent
/
Child
/
Female
/
Humans
/
Male
Idioma:
Pt
Revista:
Ciênc. Saúde Colet. (Impr.)
Asunto de la revista:
SAUDE PUBLICA
Año:
2011
Tipo del documento:
Article
País de afiliación:
Brasil
Pais de publicación:
Brasil