Your browser doesn't support javascript.
loading
The investigation of airway management capacity of v-gel and cobra-PLA in anaesthetised rabbits
Uzun, Metehan; Kiraz, Hasan Ali; Ovali, Mehmet Akif; Sahin, Hasan; Erbas, Mesut; Toman, Huseyin.
Afiliación
  • Uzun, Metehan; Çanakkale Onsekiz Mart University. Medical Faculty. Department of Physiology. Çanakkale. TR
  • Kiraz, Hasan Ali; Çanakkale Onsekiz Mart University. Medical Faculty. Department of Physiology. Çanakkale. TR
  • Ovali, Mehmet Akif; Çanakkale Onsekiz Mart University. Medical Faculty. Department of Physiology. Çanakkale. TR
  • Sahin, Hasan; Çanakkale Onsekiz Mart University. Medical Faculty. Department of Physiology. Çanakkale. TR
  • Erbas, Mesut; Çanakkale Onsekiz Mart University. Medical Faculty. Department of Physiology. Çanakkale. TR
  • Toman, Huseyin; Çanakkale Onsekiz Mart University. Medical Faculty. Department of Physiology. Çanakkale. TR
Acta cir. bras ; Acta cir. bras;30(1): 80-86, 01/2015. tab, graf
Article en En | LILACS | ID: lil-735702
Biblioteca responsable: BR1.1
ABSTRACT

PURPOSE:

To evaluate the applicability and airway management capacity of v-gel(r) and Cobra PLA in rabbit anaesthesia during assisted (AV) or controlled ventilation (CV).

METHODS:

This study was carried out in 44 adult New Zealand white rabbit. Baseline arterial pH, PaCO2 and PaO2 values were recorded. Anaesthesia was induced with 5 mg/kg xylasine and 35 mg/kg ketamine HCI combination. AV rabbits were assigned as; control (CG-AV; n=5), LMA (LMA-AV; n=5), cobra PLA (PLA-AV; n=5) and v-gel (v-gelAV; n=5). Rabbits have CV were also assigned as; ET (ET-CV; n=6), LMA (LMA-CV; n=6), cobraPLA (PLA-CV; n=6) and v-gel (v-gelCV; n=6). All measurements were repeated 1st, 5th, 15th and 30th mins during anaesthesia.

RESULTS:

The less insertion time, number of attempt and complications are recorded in v-gel applied rabbits compared to other apparatus. For arterial pH values significant differences are recorded in especially at 15th and 30th min between groups of CV (p<0.005 or p<0.001). All groups had similar results with each other during anaesthesia for PaCO2 except for LMA-CV group.

CONCLUSION:

The v-gel may be used as airway device in rabbit anaesthesia undergoing AV or CV and also can be a suitable alternative to endotracheal tubes and laryngeal mask airway. .
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: LILACS Asunto principal: Respiración Artificial / Intubación Intratraqueal / Anestesia Endotraqueal Tipo de estudio: Evaluation_studies Límite: Animals Idioma: En Revista: Acta cir. bras Asunto de la revista: Cirurgia Geral / Procedimentos Cir£rgicos Operat¢rios Año: 2015 Tipo del documento: Article / Project document País de afiliación: Turquía Pais de publicación: Brasil

Texto completo: 1 Colección: 01-internacional Base de datos: LILACS Asunto principal: Respiración Artificial / Intubación Intratraqueal / Anestesia Endotraqueal Tipo de estudio: Evaluation_studies Límite: Animals Idioma: En Revista: Acta cir. bras Asunto de la revista: Cirurgia Geral / Procedimentos Cir£rgicos Operat¢rios Año: 2015 Tipo del documento: Article / Project document País de afiliación: Turquía Pais de publicación: Brasil