Evaluation of a prototype Amplicor PCR assay for detection of human immunodeficiency virus type 1 DNA in blood samples from Tanzanian adults infected with HIV-1 subtypes A, C and D.
J Clin Virol
; 17(1): 57-63, 2000 Jun.
Article
en En
| MEDLINE
| ID: mdl-10814940
BACKGROUND: In previous evaluations, the standard Amplicor HIV-1 DNA PCR test (Roche Diagnostic Systems) has been reported to have low sensitivity for the detection of some non-B HIV-1 subtypes. It has therefore become necessary to determine the performance of commercially available as well as prototype HIV-1 PCR assays for HIV-1 DNA detection in samples from various geographical settings, in order to assess their ability to detect the different HIV-1 genotypes. OBJECTIVES: To determine the performance of the prototype Roche Amplicor version 1.5 PCR test in comparison to that of the standard Roche Amplicor PCR test for the detection of HIV-1 DNA in blood samples from HIV-1 seropositive pregnant Tanzanian women infected with various HIV-1 subtypes. STUDY DESIGN: This was a cross-sectional study done on 161 blood samples collected from 106 HIV-1 seropositive and 55 seronegative asymptomatic pregnant women attending antenatal clinic in Dar es Salaam, Tanzania. METHODS: Cell pellets for PCR were prepared from EDTA blood by the Amplicor whole blood PCR sample preparation method. Plasma was used for HIV serology by enzyme linked immunosorbent assays. Subtyping was done by the heteroduplex mobility assay (HMA) using cell pellets and/or plasma. RESULTS: The sensitivities of the prototype PCR and the standard assays were 99.1% (105/106) and 97% (99/102), respectively. All samples from 55 HIV-1 seronegative women were negative by both PCR assays. Among the 101 samples subtyped by HMA, 48 (47%) were subtype A, 30 (30%) subtype C, 20 (20%) subtype D and 3 (3%) were indeterminate. In the standard DNA PCR assay, a statistically significantly higher proportion of subtype A samples had a low level of reactivity as measured as optical density compared with the subtypes C and D samples while in the prototype assay all three subtypes showed a high level of reactivity. CONCLUSIONS: The Amplicor version 1.5 DNA PCR test has a high sensitivity for the detection of HIV-1 DNA in blood samples from Tanzanian adults. Since performance of this assay does not appear to be influenced by differences in HIV-1 subtypes A, C and D, it has the potential for use in the detection of HIV-1 DNA in samples from geographic areas where these subtypes are prevalent.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Complicaciones Infecciosas del Embarazo
/
ADN Viral
/
Infecciones por VIH
/
Reacción en Cadena de la Polimerasa
/
VIH-1
Tipo de estudio:
Diagnostic_studies
/
Evaluation_studies
/
Observational_studies
/
Prevalence_studies
/
Risk_factors_studies
Límite:
Adult
/
Female
/
Humans
/
Pregnancy
País/Región como asunto:
Africa
Idioma:
En
Revista:
J Clin Virol
Asunto de la revista:
VIROLOGIA
Año:
2000
Tipo del documento:
Article
País de afiliación:
Tanzania
Pais de publicación:
Países Bajos