Your browser doesn't support javascript.
loading
Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering.
Biederer, J; Reuter, M; Both, M; Muhle, C; Grimm, J; Graessner, J; Heller, M.
Afiliación
  • Biederer J; Department of Diagnostic Radiology, University Hospital Kiel, Arnold-Heller-Strasse 9, 24105 Kiel, Germany. juergen.biederer@rad.uni-kiel.de
Eur Radiol ; 12(2): 378-84, 2002 Feb.
Article en En | MEDLINE | ID: mdl-11870438
The aim of this study was to evaluate feasibility and limitations of two MR sequences for imaging of the lung using a semi-quantitative rating scale. Ten healthy volunteers were assessed with a breath-hold T1-weighted gradient-recalled-echo (TR/TE=129/2.2 ms, matrix 173 x 256) and a T2-weighted turbo spin-echo (TSE) sequence with respiratory triggering (TR/TE=3000-5000/120 ms, matrix 270 x 512) in axial 6-mm slices. The T1-weighted GRE protocol included a pre-saturation pulse over the mediastinal structures. Artefacts and resolution of vessel/airway structures in each lung segment were evaluated by two observers (10 volunteers, 180 segments). Cardiac and vessel pulsation artefacts predominated on T1-weighted GRE, respiration artefacts on T2-weighted TSE (lingula and middle lobe). Pre-saturation of the mediastinum reduced pulsation artefacts on T1-weighted GRE. T1-weighted GRE images were improved by bright flow signal of vessels, whereas image quality of T2-weighted TSE was reduced by black-blood effects in central parts of the lung. Delineation of lung periphery and the mediastinum was superior with T2-weighted TSE. Segmental/sub-segmental vessels (up to fourth/fifth order) and bronchi (up to third order) were identified. All 180 lung segments were imaged in diagnostic quality with at least one of the two sequences (T1-weighted GRE not diagnostic in 9 of 180, T2-weighted TSE in 4 of 180). Both sequences were found to be complementary: superior identification of gross lung anatomy with T1-weighted GRE and higher detail resolution in the periphery and the mediastinum with T2--weighted TSE.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Artefactos / Pulmón Tipo de estudio: Guideline / Prognostic_studies Límite: Adult / Female / Humans Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2002 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Alemania
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Artefactos / Pulmón Tipo de estudio: Guideline / Prognostic_studies Límite: Adult / Female / Humans Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2002 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Alemania