Reduction of polymerization contraction stress for dental composites by two-step light-activation.
Lim, B-S; Ferracane, J L; Sakaguchi, R L; Condon, J R.
Afiliación
  • Lim BS; Department of Dental Biomaterials, College of Dentistry, Seoul National University, South Korea.
Dent Mater ; 18(6): 436-44, 2002 Sep.
Article en En | MEDLINE | ID: mdl-12098572
OBJECTIVES: The goal of this study was to assess the reduction of polymerization contraction stress of composites during a two-step light-activation process and to relate this reduction to the process of polymerization shrinkage and specimen thickness. METHODS: Three test procedures were performed to compare two-step light-activation with delay with one-step continuous irradiation of composites: polymerization contraction stress using a closed-loop servohydraulic testing instrument, polymerization shrinkage by a mercury dilatometer, and degree of conversion by FTIR. For the one-step continuous curing method, the samples were light-activated for 60s at 330 mW/cm(2). For the two-step curing method, a 5s light exposure at 60 mW/cm(2) was followed by 2 min without light exposure, and then a second light exposure for 60s at 330 mW/cm(2). The same light parameters were used for measurements of stress, shrinkage, and degree of conversion. Three composites, Heliomolar, Herculite and Z100 were evaluated. The contraction stress experiments were repeated with varying thickness for Herculite using the one-step and two different two-step techniques. RESULTS: Polymerization contraction stress 10 min after light-activation was significantly reduced (P<0.05) by the two-step method: 29.7% for Heliomolar, 26.5% for Herculite, and 19.0% for Z100. Total volumetric shrinkage and degree of conversion were not significantly different for composites cured by the two different techniques. Increasing the thickness of the composite sample reduced the measured contraction stress, especially for one of the two-step curing methods. SIGNIFICANCE: A combination of low initial energy density followed by a lag period before a final high-intensity light irradiation provides a reduction of polymerization contraction stresses in dental composites. The stress reductions cannot be attributed to reductions in degree of conversion or unrestrained volumetric shrinkage.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Circonio / Dióxido de Silicio / Resinas Compuestas / Luz Límite: Humans Idioma: En Revista: Dent Mater Asunto de la revista: ODONTOLOGIA Año: 2002 Tipo del documento: Article País de afiliación: Corea del Sur Pais de publicación: Reino Unido
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Circonio / Dióxido de Silicio / Resinas Compuestas / Luz Límite: Humans Idioma: En Revista: Dent Mater Asunto de la revista: ODONTOLOGIA Año: 2002 Tipo del documento: Article País de afiliación: Corea del Sur Pais de publicación: Reino Unido