Your browser doesn't support javascript.
loading
Time course of release of inflammatory markers after coronary stenting: comparison between bare metal stent and sirolimus-eluting stent.
Kefer, Joëlle M; Galanti, Laurence M; Desmet, Sandrine; Deneys, Véronique; Hanet, Claude E.
Afiliación
  • Kefer JM; Divisions of Cardiology Haemostasis, University of Louvain, Brussels, Belgium.
Coron Artery Dis ; 16(8): 505-9, 2005 Dec.
Article en En | MEDLINE | ID: mdl-16319662
BACKGROUND: High levels of release of inflammatory markers after coronary angioplasty are predictors of late restenosis. Sirolimus-eluting stent reduces the risk of restenosis. AIM OF THE STUDY: To compare the release of inflammatory markers after coronary angioplasty with sirolimus-eluting stent and bare metal stent. METHODS: Sixteen patients with a proximal left anterior descending coronery artery stenosis were randomly assigned to receive either bare metal stent (n = 8) or sirolimus-eluting stent (n = 8). We measured simultaneously aortic and coronary sinus concentrations of the von Willebrand factor antigen, tumor necrosis factor-alpha and interleukin-6 before, immediately and after 2 h after stenting. High-sensitivity C-reactive protein and troponin-I circulating levels were measured before and 6 and 24 h after coronary angioplasty. RESULTS: Before stenting, all values were similar in both groups. The coronary sinus change of the von Willebrand factor antigen level between baseline and 2 h after stenting was + 20.1 +/- 26.9% in the bare metal stent group and -5.7 +/- 23.02% in the sirolimus-eluting stent group (P < 0.05). We observed a significant increase in the von Willebrand factor antigen (from 132.8+/-58.8 to 169 +/- 40.7%, P < 0.05) systemic concentrations 24 h after stenting in the bare metal stent group but not in the sirolimus-eluting stent group (from 140.6+/-84% to 136 +/- 39.5%), P = NS). CONCLUSION: The present study shows that a difference in the release of inflammatory markers can be detected after coronary stenting with bare metal stent or sirolimus-eluting stent. The lower release of the von Willebrand factor antigen in the coronary sinus 2 h after the procedure and the lower systemic concentrations of the von Willebrand factor antigen 24 h after stenting in the sirolimus-eluting stent group are likely to reflect a reduced production of the von Willebrand factor antigen at the site of the vascular injury.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Stents / Vasos Coronarios / Estenosis Coronaria / Reestenosis Coronaria / Revascularización Miocárdica / Antígenos Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Coron Artery Dis Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2005 Tipo del documento: Article País de afiliación: Bélgica Pais de publicación: Reino Unido
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Stents / Vasos Coronarios / Estenosis Coronaria / Reestenosis Coronaria / Revascularización Miocárdica / Antígenos Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Coron Artery Dis Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2005 Tipo del documento: Article País de afiliación: Bélgica Pais de publicación: Reino Unido