Embedded fiber-optic Fabry-Perot ultrasound sensor.
IEEE Trans Ultrason Ferroelectr Freq Control
; 37(4): 302-6, 1990.
Article
en En
| MEDLINE
| ID: mdl-18285045
A fiber-optic ultrasound sensor is presented. The sensor consists of a continuous length of single-mode optical fiber with a built-in Fabry-Perot interferometer. The acoustic pressure produces changes in the index of refraction along the interferometer cavity through the strain-optic effect, thus modulating the reflected power of the light propagating in the fiber. The dielectric internal mirrors that form the interferometer are fabricated by joining a fiber coating with a TiO(2) film at one end to an uncoated fiber by electric arc fusion splicing. Experimental results have been obtained for sensors embedded in plastic and graphite composite materials, using ultrasound waves in the range from 100 kHz to 5 MHz. Values for the optical phase shift amplitude as large as 0.5 rad were obtained at an acoustic frequency of 200 kHz for a 1.1-cm-long interferometer embedded in plastic.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Idioma:
En
Revista:
IEEE Trans Ultrason Ferroelectr Freq Control
Asunto de la revista:
MEDICINA NUCLEAR
Año:
1990
Tipo del documento:
Article
Pais de publicación:
Estados Unidos