First results of an eye lens dosimetry survey in an interventional cardiology department.
J Radiol Prot
; 35(2): 467-72, 2015 Jun.
Article
en En
| MEDLINE
| ID: mdl-26052799
The eye lens annual dose limit for exposed personnel to ionizing radiation has recently been revised by the ICRP--International Commission on Radiological Protection and the proposed new limit has been accepted by European legislation through the Council Directive 2013/59/EURATOM 2013. Among medical exposed personnel, the staff performing interventional cardiology are usually affected by relevant doses. For this reason a survey, employing dosemeters characterized in terms of H(p)(3), was performed in order to get the order of magnitude of the doses received by the eye lens, at least as a first guess.The survey showed that the annual dose limit can easily be reached if a proper radiation protection approach is not implemented.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Dosimetría Termoluminiscente
/
Cateterismo Cardíaco
/
Radiografía Intervencional
/
Exposición Profesional
/
Exposición a la Radiación
/
Cristalino
Tipo de estudio:
Diagnostic_studies
/
Evaluation_studies
País/Región como asunto:
Europa
Idioma:
En
Revista:
J Radiol Prot
Asunto de la revista:
RADIOLOGIA
Año:
2015
Tipo del documento:
Article
País de afiliación:
Italia
Pais de publicación:
Reino Unido