Your browser doesn't support javascript.
loading
Cardiovascular magnetic resonance in patients with magnetic resonance conditional pacemaker systems at 1.5 T: influence of pacemaker related artifacts on image quality including first pass perfusion, aortic and mitral valve assessment, flow measurement, short tau inversion recovery and T1-weighted imaging.
Klein-Wiele, Oliver; Garmer, Marietta; Busch, Martin; Mateiescu, Serban; Urbien, Rhyan; Barbone, Gianluca; Kara, Kaffer; Schulte-Hermes, Michael; Metz, Frauke; Hailer, Birgit; Grönemeyer, Dietrich.
Afiliación
  • Klein-Wiele O; Department of Cardiology, Grönemeyer Institut Bochum, University of Witten/Herdecke, Universitätsstraße 142, 44799, Bochum, Germany. o.klein-wiele@kk-essen.de.
  • Garmer M; Department of Cardiology, Katholisches Klinikum Essen, University of Witten/Herdecke, Hülsmannstraße 17, 45355, Essen, Germany. o.klein-wiele@kk-essen.de.
  • Busch M; Department of Radiology, Grönemeyer Institut Bochum, University of Witten/Herdecke, Universitätsstraße 142, 44799, Bochum, Germany.
  • Mateiescu S; Department of Radiology, Grönemeyer Institut Bochum, University of Witten/Herdecke, Universitätsstraße 142, 44799, Bochum, Germany.
  • Urbien R; Department of Radiology, Grönemeyer Institut Bochum, University of Witten/Herdecke, Universitätsstraße 142, 44799, Bochum, Germany.
  • Barbone G; Department of Cardiology, Katholisches Klinikum Essen, University of Witten/Herdecke, Hülsmannstraße 17, 45355, Essen, Germany.
  • Kara K; Department of Cardiology, Katholisches Klinikum Essen, University of Witten/Herdecke, Hülsmannstraße 17, 45355, Essen, Germany.
  • Schulte-Hermes M; Cardiovascular Centre, Josef Hospital, University of Bochum, Gudrunstr. 56, 44791, Bochum, Germany.
  • Metz F; Department of Cardiology, Prosper-Hospital Recklinghausen, University of Witten/Herdecke, Mühlenstraße 27, 45659, Recklinghausen, Germany.
  • Hailer B; Department of Radiology, Grönemeyer Institut Bochum, University of Witten/Herdecke, Universitätsstraße 142, 44799, Bochum, Germany.
  • Grönemeyer D; Department of Cardiology, Katholisches Klinikum Essen, University of Witten/Herdecke, Hülsmannstraße 17, 45355, Essen, Germany.
Int J Cardiovasc Imaging ; 33(3): 383-394, 2017 Mar.
Article en En | MEDLINE | ID: mdl-27815793

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Válvula Aórtica / Marcapaso Artificial / Arritmias Cardíacas / Interpretación de Imagen Asistida por Computador / Artefactos / Imagen por Resonancia Cinemagnética / Circulación Coronaria / Imagen de Perfusión Miocárdica / Válvula Mitral Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Int J Cardiovasc Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2017 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Válvula Aórtica / Marcapaso Artificial / Arritmias Cardíacas / Interpretación de Imagen Asistida por Computador / Artefactos / Imagen por Resonancia Cinemagnética / Circulación Coronaria / Imagen de Perfusión Miocárdica / Válvula Mitral Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Int J Cardiovasc Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2017 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Estados Unidos