Your browser doesn't support javascript.
loading
A New Electrochemical System Based on a Flow-Field Shaped Solid Electrode and 3D-Printed Thin-Layer Flow Cell: Detection of Pb2+ Ions by Continuous Flow Accumulation Square-Wave Anodic Stripping Voltammetry.
Sun, Qianwen; Wang, Jikui; Tang, Meihua; Huang, Liming; Zhang, Zhiyi; Liu, Chang; Lu, Xiaohua; Hunter, Kenneth W; Chen, Guosong.
Afiliación
  • Sun Q; College of Chemistry and Molecular Engineering, Nanjing Tech University , Nanjing 210009, China.
  • Wang J; College of Chemistry and Molecular Engineering, Nanjing Tech University , Nanjing 210009, China.
  • Tang M; College of Chemistry and Molecular Engineering, Nanjing Tech University , Nanjing 210009, China.
  • Huang L; Department of Microbiology and Immunology, School of Medicine, University of Nevada , Reno, Nevada 89557, United States.
  • Zhang Z; College of Chemistry and Molecular Engineering, Nanjing Tech University , Nanjing 210009, China.
  • Liu C; College of Chemistry and Molecular Engineering, Nanjing Tech University , Nanjing 210009, China.
  • Lu X; College of Chemistry and Molecular Engineering, Nanjing Tech University , Nanjing 210009, China.
  • Hunter KW; Department of Microbiology and Immunology, School of Medicine, University of Nevada , Reno, Nevada 89557, United States.
  • Chen G; College of Chemistry and Molecular Engineering, Nanjing Tech University , Nanjing 210009, China.
Anal Chem ; 89(9): 5024-5029, 2017 05 02.
Article en En | MEDLINE | ID: mdl-28393530
Here we describe a new and sensitive flow electrochemical detection system that employs a novel flow-field shaped solid electrode (FFSSE). The system was constructed with a 3D-printed thin-layer flow cell (TLFC) and a flat screen-printed FFSSE with USB connection. This interface facilitates continuous flow accumulation square-wave anodic stripping voltammetry (ASV). The flow distribution in the working space of TLFC was simulated using the finite element method (FEM) and the shape and configuration of electrodes were optimized accordingly. We demonstrated the electrochemical determination of Pb2+ using this newly designed TLFC-FFSSE detection system without removal of oxygen from samples. This TLFC-FFSSE based system showed an attractive stripping voltammetric performance compared to a traditional ASV based method. A linear range for detection of Pb2+ was found to be 0.5-100 µg/L (0.5 to 100 ppb) and a detection limit of 0.2 µg/L (0.2 ppb) was achieved in the presence of bismuth as codeposition metal. The system was further applied to detect Pb2+ in biological broths of methane fermentation. The electrochemical detection results were consistent with that obtained from atomic fluorescence spectroscopy (AFS) analysis and the average recovery was found to be 95.5-106.5% using a standard addition method. This new flow electrochemical detection system showed better sensitivity and reproducibility compared to a traditional ASV based method. Such a system offers great potential for on-site and real-time detection of heavy metals where compact, inexpensive, robust, and low-volume analysis is required.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Anal Chem Año: 2017 Tipo del documento: Article País de afiliación: China Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Anal Chem Año: 2017 Tipo del documento: Article País de afiliación: China Pais de publicación: Estados Unidos