A new dispersion interferometer on HL-2A.
Wang, H X; Zhou, Y; Li, Y; Li, Y G; Yi, J; Deng, Z C; Gao, Z; Wu, T Y; Yin, Z J; Akiyama, T.
Afiliación
  • Wang HX; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Zhou Y; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Li Y; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Li YG; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Yi J; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Deng ZC; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Gao Z; Department of Engineering Physics, Tsinghua University, Beijing 10084, China.
  • Wu TY; State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei 230026, China.
  • Yin ZJ; State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei 230026, China.
  • Akiyama T; National Institute for Fusion Science, 322-6 Oroshi-cho, Toki-shi, Gifu 509-5292, Japan.
Rev Sci Instrum ; 88(10): 103502, 2017 Oct.
Article en En | MEDLINE | ID: mdl-29092472
In order to avoid a fringe jump caused by high plasma density and pellet injection [Y. Zhou et al., Rev. Sci. Instrum. 87, 11E107 (2016)], a new CO2 dispersion interferometer is designed and commissioned on HL-2A for average line-density measurement and density feedback control. The second harmonic technology in this system eliminates the phase shift caused by mechanical vibration. Signals are processed by a digital phase comparator and can be monitored in real time. A series of experiments are conducted to study the characteristics of the system such as a second harmonic coefficient and long-term stability. The resolution of density measurement is less than 8 × 1017/m3, and the experiment result on HL-2A demonstrates the interferometer's capability to track plasma density evolution with rapid change. The system also shows good stability against mechanical vibrations.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2017 Tipo del documento: Article País de afiliación: China Pais de publicación: Estados Unidos