Your browser doesn't support javascript.
loading
Value of contrast-enhanced ultrasound in the differential diagnosis of gallbladder lesion.
Zhang, Hui-Ping; Bai, Min; Gu, Ji-Ying; He, Ying-Qian; Qiao, Xiao-Hui; Du, Lian-Fang.
Afiliación
  • Zhang HP; Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200080, China.
  • Bai M; Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200080, China.
  • Gu JY; Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200080, China.
  • He YQ; Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200080, China.
  • Qiao XH; Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200080, China.
  • Du LF; Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200080, China. du_lf@163.com.
World J Gastroenterol ; 24(6): 744-751, 2018 Feb 14.
Article en En | MEDLINE | ID: mdl-29456413
AIM: To describe contrast-enhanced ultrasound (CEUS) features and evaluate differential diagnosis value of CEUS and conventional ultrasound for patients with benign and malignant gallbladder lesions. METHODS: This study included 105 gallbladder lesions. Before surgical resection and pathological examination, conventional ultrasound and CEUS were performed to examine for lesions. Then, all the lesions were diagnosed as (1) benign, (2) probably benign, (3) probably malignant or (4) malignant using both conventional ultrasound and CEUS. The CEUS features of these gallbladder lesions were analyzed and diagnostic efficiency between conventional ultrasound and CEUS was compared. RESULTS: There were total 17 cases of gallbladder cancer and 88 cases of benign lesion. Some gallbladder lesions had typical characteristics on CEUS (e.g., gallbladder adenomyomatosis had typical characteristics of small nonenhanced areas on CEUS). The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of CEUS were 94.1%, 95.5%, 80.0%, 98.8% and 95.2%, respectively. These were significantly higher than conventional ultrasound (82.4%, 89.8%, 60.9%, 96.3% and 88.6%, respectively). CEUS had an accuracy of 100% for gallbladder sludge and CEUS helped in differential diagnosis among gallbladder polyps, gallbladder adenoma and gallbladder cancer. CONCLUSION: CEUS may provide more useful information and improve the diagnosis efficiency for the diagnosis of gallbladder lesions than conventional ultrasound.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ultrasonografía / Medios de Contraste / Vesícula Biliar / Enfermedades de la Vesícula Biliar Tipo de estudio: Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: World J Gastroenterol Asunto de la revista: GASTROENTEROLOGIA Año: 2018 Tipo del documento: Article País de afiliación: China Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ultrasonografía / Medios de Contraste / Vesícula Biliar / Enfermedades de la Vesícula Biliar Tipo de estudio: Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: World J Gastroenterol Asunto de la revista: GASTROENTEROLOGIA Año: 2018 Tipo del documento: Article País de afiliación: China Pais de publicación: Estados Unidos