Your browser doesn't support javascript.
loading
Detection of clinically relevant immune checkpoint markers by multicolor flow cytometry.
Cunningham, Rachel A; Holland, Martha; McWilliams, Emily; Hodi, Frank Stephen; Severgnini, Mariano.
Afiliación
  • Cunningham RA; Department of Medical Oncology, Center for Immuno-Oncology, Dana-Farber Cancer Institute, 450 Brookline, Ave Mayer Building 305, Boston, MA 02215, USA.
  • Holland M; Department of Medical Oncology, Center for Immuno-Oncology, Dana-Farber Cancer Institute, 450 Brookline, Ave Mayer Building 305, Boston, MA 02215, USA.
  • McWilliams E; Department of Medical Oncology, Center for Immuno-Oncology, Dana-Farber Cancer Institute, 450 Brookline, Ave Mayer Building 305, Boston, MA 02215, USA.
  • Hodi FS; Department of Medical Oncology, Center for Immuno-Oncology, Dana-Farber Cancer Institute, 450 Brookline, Ave Mayer Building 305, Boston, MA 02215, USA.
  • Severgnini M; Department of Medical Oncology, Center for Immuno-Oncology, Dana-Farber Cancer Institute, 450 Brookline, Ave Mayer Building 305, Boston, MA 02215, USA.
J Biol Methods ; 6(2): e114, 2019.
Article en En | MEDLINE | ID: mdl-31453261
ABSTRACT
As checkpoint inhibitor immunotherapies gain traction among cancer researchers and clinicians, the need grows for assays that can definitively phenotype patient immune cells. Herein, we present an 8-color flow cytometry panel for lineage and immune checkpoint markers and validate it using healthy human donor peripheral blood mononuclear cells (PBMCs). Flow cytometry data was generated on a BD LSR Fortessa and supported by Luminex multiplex soluble immunoassay. Our data showed significant variation between donors at both baseline and different stages of activation, as well as a trend in increasing expression of checkpoint markers on stimulated CD4+ and CD8+ T-cells with time. Soluble immune checkpoint quantification assays revealed that LAG-3, TIM-3, CTLA-4, and PD-1 soluble isoforms are upregulated after stimulation. This 8-color flow cytometry panel, supported here by soluble immunoassay, can be used to identify and evaluate immune checkpoints on T-lymphocytes in cryopreserved human PBMC samples. This panel is ideal for characterizing checkpoint expression in clinical samples for which cryopreservation is necessary.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: J Biol Methods Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: J Biol Methods Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos