Your browser doesn't support javascript.
loading
Application of Factorial and Doehlert Designs for the Optimization of the Simultaneous Separation and Determination of Antimigraine Drugs in Pharmaceutical Formulations by RP-HPLC-UV.
Jebali, Sami; Belgacem, Chaouki; Louhaichi, Mohamed Radhouen; Bahri, Senda; Latrous El Atarche, Latifa.
Afiliación
  • Jebali S; Laboratoire National de Contrôle des Médicaments, 11 Bis Rue Jebel Lakhdar Bab Saadoun, 1006 Tunis, Tunisia.
  • Belgacem C; Université de Tunis El Manar, Faculté des Sciences de Tunis, Laboratoire de Chimie Analytique et Electrochimie, Campus Universitaire El Manar II 2092, Tunis, Tunisia.
  • Louhaichi MR; Université de Tunis El Manar, Faculté des Sciences de Tunis, Laboratoire de Chimie Analytique et Electrochimie, Campus Universitaire El Manar II 2092, Tunis, Tunisia.
  • Bahri S; Institut National de Recherche et d' Analyse Physico-Chimique, Technopole, 2020 Sidi Thabet, Ariana, Tunis, Tunisia.
  • Latrous El Atarche L; Laboratoire National de Contrôle des Médicaments, 11 Bis Rue Jebel Lakhdar Bab Saadoun, 1006 Tunis, Tunisia.
Int J Anal Chem ; 2019: 9685750, 2019.
Article en En | MEDLINE | ID: mdl-31511775
A sensitive, precise, accurate, and specific isocratic reversed-phase high-performance liquid chromatographic (RP-HPLC) method for the simultaneous separation and determination of zolmitriptan, naratriptan, dihydroergotamine, ketotifen, and pizotifen in pharmaceutical formulations has been developed and validated. An experimental design was applied for the optimization of the chromatographic parameters. A two-level full factorial 2 k was used for studying the interaction between the variables to be optimized: the percentage of acetonitrile in the mobile phase, mobile-phase pH, nature of the buffer, and column oven temperature. The most significant parameters are the percentage of acetonitrile and the mobile-phase pH. These significant parameters were optimized using the Doehlert matrix. The optimum separation was achieved by means of a Waters XBridge C18 column (250 mm × 4.6 mm, 5 µm) with a mobile phase consisting of acetonitrile and a 10 mM sodium perchlorate buffer (38 : 62, v/v) at a flow rate of 1.0 mL·min-1 and UV detection at 220 nm. The selectivity, method linearity, accuracy, and precision were examined as part of the method validation. The described method shows excellent linearity over a range of 30 to 70 µg·mL-1 for all compounds with correlation coefficients higher than 0.995. The standard deviations of the intraday and interday precision were between 0.75 and 1.94%. The validated method was successfully applied to perform routine analysis of these compounds in different pharmaceutical products such as syrups and tablets. In the presence of some preservatives, it was found that there were no peaks at the related peak locations.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Int J Anal Chem Año: 2019 Tipo del documento: Article País de afiliación: Túnez Pais de publicación: Egipto

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Int J Anal Chem Año: 2019 Tipo del documento: Article País de afiliación: Túnez Pais de publicación: Egipto