Your browser doesn't support javascript.
loading
Comparison of visual outcomes after bilateral implantation of two intraocular lenses with distinct diffractive optics.
de Medeiros, André Lins; Jones Saraiva, Flavio; Iguma, Camila Ishii; Kniggendorf, Danilo Varela; Alves, Guilherme; Chaves, Mario Augusto Pereira Dias; Vilar, Cesar; Motta, Antonio Francisco Pimenta; Carricondo, Pedro Carlos; Takashi Nakano, Celso; Nosé, Walton; Hida, Wilson Takashi.
Afiliación
  • de Medeiros AL; Cataract Sector, Renato Ambrosio Eye Research Center, Brasília, DF, Brazil.
  • Jones Saraiva F; Cataract Sector, Hospital Oftalmológico De Brasília, Brasília, DF, Brazil.
  • Iguma CI; Cataract Sector, Hospital Oftalmológico De Brasília, Brasília, DF, Brazil.
  • Kniggendorf DV; Cataract Sector, Renato Ambrosio Eye Research Center, Brasília, DF, Brazil.
  • Alves G; Cataract Sector, Hospital Oftalmológico De Brasília, Brasília, DF, Brazil.
  • Chaves MAPD; Cataract Sector, Renato Ambrosio Eye Research Center, Brasília, DF, Brazil.
  • Vilar C; Cataract Sector, Renato Ambrosio Eye Research Center, Brasília, DF, Brazil.
  • Motta AFP; Cataract Sector, Renato Ambrosio Eye Research Center, Brasília, DF, Brazil.
  • Carricondo PC; Cataract Sector, Renato Ambrosio Eye Research Center, Brasília, DF, Brazil.
  • Takashi Nakano C; Cataract Sector, Renato Ambrosio Eye Research Center, Brasília, DF, Brazil.
  • Nosé W; Cataract Sector, Renato Ambrosio Eye Research Center, Brasília, DF, Brazil.
  • Hida WT; Cataract Sector, Renato Ambrosio Eye Research Center, Brasília, DF, Brazil.
Clin Ophthalmol ; 13: 1657-1663, 2019.
Article en En | MEDLINE | ID: mdl-31695317
ABSTRACT

PURPOSE:

The aim of this study was to compare the visual outcomes and subjective visual quality between bilateral implantation of an extended depth of focus intraocular lens, J&J Vision Tecnis Symfony® ZXR00 (Group A) and bilateral implantation of a diffractive trifocal intraocular lens, Alcon Acrysof IQ PanOptix® TNFT00 (Group B).

METHODS:

This prospective, nonrandomized, comparative study of consecutive cases assessed 52 eyes of 26 patients operated on by the same surgeon (WTH) and binocularly implanted with multifocal intraocular lenses between May 2016 and July 2018. Binocular visual acuity for far, intermediate and near was tested in all cases. Ophthalmological evaluation included the measurement of binocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA) at 40 cm, uncorrected intermediate visual acuity (UIVA) at 70 cm, monocular visual defocus curve and the quality of life (QoL) questionnaire, National Eye Institute Visual Functioning Questionnaire - 25 ( NEI-VFQ 25).

RESULTS:

Postoperative UDVA was 0.00 and 0.09 logMAR (P<0.001), UIVA was 0.20 and 0.39 logMAR (P<0.001) and UNVA was 0.16 and -0.01 logMAR (P<0.001) in groups A and B, respectively; postoperative CDVA was -0.05 and 0.06 logMAR (P<0.001) in groups A and B, respectively.

CONCLUSION:

Both groups reported good subjective quality of vision regarding long, intermediate and short distances. Group A had a better performance for binocular UDVA, UIVA at 70 cm and CDVA, while regarding the monocular defocus curve, Group A outperformed Group B for long distances. Furthermore, Group B surpassed it in the short to very short distances, between the range of ≥2.00 D to 5.00 D of vergence. While Group A had a better performance regarding the vergences between 0.00 and 1.00 D (P<0.05) and at the vergence of +2.50 D (P=0.007). Group B outran Group A for UNVA at 40 cm.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Aspecto: Patient_preference Idioma: En Revista: Clin Ophthalmol Año: 2019 Tipo del documento: Article País de afiliación: Brasil

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Aspecto: Patient_preference Idioma: En Revista: Clin Ophthalmol Año: 2019 Tipo del documento: Article País de afiliación: Brasil