Your browser doesn't support javascript.
loading
Follow-Up 18F-FDG PET/CT versus Contrast-Enhanced CT after Ablation of Liver Metastases of Colorectal Carcinoma-A Cost-Effectiveness Analysis.
Schnitzer, Moritz L; Froelich, Matthias F; Gassert, Felix G; Huber, Thomas; Gresser, Eva; Schwarze, Vincent; Nörenberg, Dominik; Todica, Andrei; Rübenthaler, Johannes.
Afiliación
  • Schnitzer ML; Department of Radiology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany.
  • Froelich MF; Department of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany.
  • Gassert FG; Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany.
  • Huber T; Department of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany.
  • Gresser E; Department of Radiology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany.
  • Schwarze V; Department of Radiology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany.
  • Nörenberg D; Department of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany.
  • Todica A; Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany.
  • Rübenthaler J; Department of Radiology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany.
Cancers (Basel) ; 12(9)2020 Aug 27.
Article en En | MEDLINE | ID: mdl-32867107
PURPOSE: After a percutaneous ablation of colorectal liver metastases (CRLM), follow-up investigations to evaluate potential tumor recurrence are necessary. The aim of this study was to analyze whether a combined 18F-Fluordesoxyglucose positron emission tomography-computed tomography (18F-FDG PET/CT) scan is cost-effective compared to a contrast-enhanced computed tomography (CE-CT) scan for detecting local tumor progression. MATERIALS AND METHODS: A decision model based on Markov simulations that estimated lifetime costs and quality-adjusted life years (QALYs) was developed. Model input parameters were obtained from the recent literature. Deterministic sensitivity analysis of diagnostic parameters based on a Monte-Carlo simulation with 30,000 iterations was performed. The willingness-to-pay (WTP) was set to $100,000/QALY. RESULTS: In the base-case scenario, CE-CT resulted in total costs of $28,625.08 and an efficacy of 0.755 QALYs, whereas 18F-FDG PET/CT resulted in total costs of $29,239.97 with an efficacy of 0.767. Therefore, the corresponding incremental cost-effectiveness ratio (ICER) of 18F-FDG PET/CT was $50,338.96 per QALY indicating cost-effectiveness based on the WTP threshold set above. The results were stable in deterministic and probabilistic sensitivity analyses. CONCLUSION: Based on our model, 18F-FDG PET/CT can be considered as a cost-effective imaging alternative for follow-up investigations after percutaneous ablation of colorectal liver metastases.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Health_economic_evaluation / Prognostic_studies Aspecto: Patient_preference Idioma: En Revista: Cancers (Basel) Año: 2020 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Health_economic_evaluation / Prognostic_studies Aspecto: Patient_preference Idioma: En Revista: Cancers (Basel) Año: 2020 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Suiza