[Utility of the type 3 portable monitor for the diagnosis of sleep disordered breathing in patients with stable heart failure].
Zhonghua Yi Xue Za Zhi
; 101(22): 1676-1682, 2021 Jun 15.
Article
en Zh
| MEDLINE
| ID: mdl-34126716
Objective: To evaluate the utility of a type 3 portable monitor (PM) at home for the diagnosis of sleep disordered breathing (SDB) in patients with stable congestive heart failure (CHF). Methods: Seventy-six consecutive patients with CHF (61 males, 15 females, mean±standard deviation age (57.0±16.9) years) were enrolled from the sleep center of Peking university People's Hospital during January 2016 to January 2019, and underwent overnight, unattended home sleep apnea testing (HSAT) with a portable monitor followed by an overnight simultaneous polysomnogram (PSG) with in-laboratory portable monitor (in-lab PM) recording within one week. The consistency of apnea hypopnea index (AHI), obstructive sleep apnea index (OAI), central sleep apnea index (CAI) between HSAT and PSG as well as the in-lab PM and PSG were analyzed by Bland-Altman plot; the sensitivity and specificity of PM for the diagnosis of SDB in patients with CHF were evaluated. Results: The number of patients included in the final analysis were 65 in HSAT, 63 in in-lab PM and 65 in PSG. AHI [M(Q1,Q3)] was 26.1 (10.9,40.1) events/h by HSAT, 27.9 (11.3,43.2) events/h by in-lab PM, both were not different from AHI 29.0 (10.2,45.0) events/h by PSG (P>0.05). The AHI, OAI and CAI assessed by HSAT correlated significantly with those by PSG (r=0.892, 0.903, 0.831, P<0.05). Bland-Altman analysis of AHI, OAI, CAI by PSG versus HSAT showed a mean difference of 3.1 events/h, 0.8 events/h, 1.2 events/h; limits of consistency were -15.2 to 21.4 events/h, -9.7 to 11.3 events/h, -10.9 to 13.2 events/h, respectively. Based on a threshold of AHI ≥5 events/h, HSAT had 94.6% sensitivity, 75% specificity, compared to PSG. For detecting Cheyne-Stokes respiration (CSR), a sensitivity of 96.4%,a specificity of 97.2% were achieved, compared to PSG. Conclusion: Type 3 PM can be used to diagnose SDB in patients with CHF.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Síndromes de la Apnea del Sueño
/
Apnea Obstructiva del Sueño
/
Insuficiencia Cardíaca
Tipo de estudio:
Diagnostic_studies
Límite:
Adult
/
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
Zh
Revista:
Zhonghua Yi Xue Za Zhi
Año:
2021
Tipo del documento:
Article
País de afiliación:
China
Pais de publicación:
China