Remote check test battery for cochlear implant recipients: proof of concept study.
Maruthurkkara, Saji; Allen, Agnes; Cullington, Helen; Muff, Joanne; Arora, Komal; Johnson, Susan.
Afiliación
  • Maruthurkkara S; Cochlear Limited, Sydney, Australia.
  • Allen A; Scottish Cochlear Implant Programme, Kilmarnock, UK.
  • Cullington H; Auditory Implant Service, University of Southampton, Southampton, UK.
  • Muff J; Emmeline Centre for Hearing Implants, Cambridge, UK.
  • Arora K; Cochlear Limited, Melbourne, Australia.
  • Johnson S; Nottingham Auditory Implant Programme, Nottingham, UK.
Int J Audiol ; 61(6): 443-452, 2022 06.
Article en En | MEDLINE | ID: mdl-34431430
OBJECTIVES: (1) To investigate the remote check test battery, designed for self-administration by cochlear implant (CI) recipients, parents/caregivers, to determine if the results give adequate information for clinicians to decide the necessity of an appointment and to capture suggestions for improvement. (2) To gauge acceptance of remote monitoring by CI-recipients and their parents/caregivers. DESIGN: Prospective, multicentre, un-blinded, non-randomized, single-subject, repeated-measures evaluation. The test battery includes an implant-site photograph, impedance measurements, datalogs, questionnaires, speech perception and aided threshold tests. Clinicians reviewed test battery results, followed by a clinical appointment with each CI-recipient, and reported if the battery identified all the issues. Study sample: n = 93 CI-recipients (73 adults, 20 children) and 28 clinicians. RESULTS: The test battery identified 94% (615/656) of all issues. The test battery and clinician observations agreed in 99% (92/93) of cases on the need for a clinic visit. For 68% (63/93) of cases, the test battery identified all clinician observed issues. The majority (77%, 72/93) of recipients would be satisfied if clinic visits were based on their test battery results. A significantly high proportion agreed that remote monitoring was more convenient than clinic visits and could result in travel, time and cost reductions. CONCLUSION: This is the first comprehensive test battery designed for CI-recipient remote monitoring.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Percepción del Habla / Implantes Cocleares / Implantación Coclear Tipo de estudio: Clinical_trials / Observational_studies Límite: Adult / Child / Humans Idioma: En Revista: Int J Audiol Asunto de la revista: AUDIOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Australia Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Percepción del Habla / Implantes Cocleares / Implantación Coclear Tipo de estudio: Clinical_trials / Observational_studies Límite: Adult / Child / Humans Idioma: En Revista: Int J Audiol Asunto de la revista: AUDIOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Australia Pais de publicación: Reino Unido