An ultrafast piezoelectric Z-scanner with a resonance frequency above 1.1 MHz for high-speed atomic force microscopy.
Shimizu, Masahiro; Okamoto, Chihiro; Umeda, Kenichi; Watanabe, Shinji; Ando, Toshio; Kodera, Noriyuki.
Afiliación
  • Shimizu M; WPI Nano Life Science Institute (WPI-NanoLSI), Kanazawa University, Kakuma-machi, Kanazawa 920-1192, Japan.
  • Okamoto C; Department of Physics, Institute of Science and Engineering, Kanazawa University, Kakuma-machi, Kanazawa 920-1192, Japan.
  • Umeda K; WPI Nano Life Science Institute (WPI-NanoLSI), Kanazawa University, Kakuma-machi, Kanazawa 920-1192, Japan.
  • Watanabe S; WPI Nano Life Science Institute (WPI-NanoLSI), Kanazawa University, Kakuma-machi, Kanazawa 920-1192, Japan.
  • Ando T; WPI Nano Life Science Institute (WPI-NanoLSI), Kanazawa University, Kakuma-machi, Kanazawa 920-1192, Japan.
  • Kodera N; WPI Nano Life Science Institute (WPI-NanoLSI), Kanazawa University, Kakuma-machi, Kanazawa 920-1192, Japan.
Rev Sci Instrum ; 93(1): 013701, 2022 Jan 01.
Article en En | MEDLINE | ID: mdl-35104993
The Z-scanner is the major component limiting the speed performance of all current high-speed atomic force microscopy systems. Here, we present an ultrafast piezoelectric Z-scanner with a resonance frequency above 1.1 MHz, achieving a record response time of ∼0.14 µs, approximately twice as fast as conventional piezoelectric-based Z-scanners. In the mechanical design, a small piezo-stack is supported at its bottom four vertices on a cone-like hollow, allowing the resonance frequency of the Z-scanner to remain as high as that of the piezo in free vibration. Its maximum displacement, ∼190 nm at 50 V, is large enough for imaging bio-molecules. For imaging bio-molecules in a buffer solution, the upper half of the Z-scanner is wrapped in a thin film resistant to water and chemicals, providing an excellent waterproof and mechanical durability without lowering the resonance frequency. We demonstrate that this Z-scanner can observe actin filaments, fragile biological polymers, for more than five times longer than the conventional Z-scanner at a tip velocity of 800 µm/s.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vibración / Agua Idioma: En Revista: Rev Sci Instrum Año: 2022 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vibración / Agua Idioma: En Revista: Rev Sci Instrum Año: 2022 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Estados Unidos