Your browser doesn't support javascript.
loading
A high-throughput magnetic-based pipette tip microextraction as an alternative to conventional pipette tip strategies: Determination of testosterone in human saliva as a proof-of-concept.
Grau, José; Benedé, Juan L; Chisvert, Alberto; Salvador, Amparo.
Afiliación
  • Grau J; GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain.
  • Benedé JL; GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain.
  • Chisvert A; GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain. Electronic address: alberto.chisvert@uv.es.
  • Salvador A; GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain.
Anal Chim Acta ; 1221: 340117, 2022 Aug 15.
Article en En | MEDLINE | ID: mdl-35934400
In this work, a lab-made and affordable high-throughput pipette tip microextraction strategy is presented. In this approach, a magnetic sorbent is quickly dispersed in the sample by means of a disperser solvent and the resulting dispersion is immediately aspirated into a pipette tip containing a small neodymium magnet inside, which entraps the magnetic sorbent containing the analytes. The sample is then discarded, and the subsequent cleaning and desorption steps are conducted by aspirating/dispensing the suitable solvents. This methodology provides satisfactory results when compared with previous pipette tip extraction strategies (i.e., pipette-tip solid-phase extraction and dispersive pipette extraction). Furthermore, it requires a minimum number of aspirating/dispensing cycles, thus benefiting the ergonomics for the operator, and it is not commercially dependent. This new approach has been tested by measuring testosterone levels in saliva of volunteers as a proof-of-concept. In this regard, a magnetic composite made of CoFe2O4 magnetic nanoparticles embedded in octadecyl bonded silica microparticles was employed as sorbent material. Testosterone was quantified by liquid chromatography coupled to tandem mass spectrometry. Under the optimized conditions, low limits of detection and quantification (7.5 ng L-1 and 24.8 ng L-1, respectively), good repeatability (RSD <9%) and relative recoveries between 82 and 106% were obtained with just one adsorption and two desorption cycles, which requires few seconds per sample. In order to increase even more the sample throughput, a multichannel pipette was also evaluated.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Testosterona / Microextracción en Fase Líquida Límite: Humans Idioma: En Revista: Anal Chim Acta Año: 2022 Tipo del documento: Article País de afiliación: España Pais de publicación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Testosterona / Microextracción en Fase Líquida Límite: Humans Idioma: En Revista: Anal Chim Acta Año: 2022 Tipo del documento: Article País de afiliación: España Pais de publicación: Países Bajos