A predictive model for first-trimester pregnancy inception after IVF-ET based on multimodal ultrasound evaluation of endometrial receptivity.
BMC Med Imaging
; 22(1): 158, 2022 09 04.
Article
en En
| MEDLINE
| ID: mdl-36058920
BACKGROUND: In-vitro fertilization-embryo transfer (IVF-ET) is a commonly used assisted reproductive technology. Its success depends on many factors, including endometrial receptivity. Endometrial receptivity can be evaluated by ultrasound, endometrial biopsy, and magnetic resonance imaging. Compared with the latter two methods, ultrasound has the advantages of wide availability, non-invasiveness, and low cost. Three-dimensional (3D) ultrasound imaging examines endometrial thickness, morphology, and blood vessels, which are associated with the success of embryo implantation. However, there are no reports of endometrial receptivity assessment by 3D ultrasound. Therefore, we aimed to evaluate endometrial receptivity using 3D ultrasound and construct a predictive model for first-trimester pregnancy inception following IVF-ET. METHODS: We performed a prospective observational study on infertile women who underwent IVF-ET between December 2019 and February 2021. These women had 3D ultrasound evaluations, measuring endometrial thickness, volume, pattern, morphology, peristalsis, uterine artery blood flow index, sub-endometrial blood flow index, and distribution pattern. We recorded the occurrence of first-trimester pregnancies in these women. Using Akaike information criterion (AIC) and backward stepwise regression, a first-trimester pregnancy prediction model was constructed based on the minimum AIC value and validated internally and externally. RESULTS: 111 women were enrolled, with 103 included in the analysis. Univariate and multiple logistic regression analyses showed that endometrial thickness and vascularization flow index (VFI) were independent factors associated with the occurrence of a pregnancy. The final prediction model corresponding to the minimum AIC value (65.166) was Y = - 6.131-0.182endometrial thickness + 0.542endometrial volume + 4.374VFI + 0.132age. In the test set, modeling cohort, and external validation cohort, the model showed satisfactory differentiation, with C index of 0.841 (95%CI 0.699-0.817), 0.727 (95%CI 0.619-0.815), and 0.745 (95%CI 0.671-0.840), respectively. The Hosmer-Lemeshow goodness of fit tests reported P = 0.865, 0.139, and 0.070, respectively, indicating a high agreement with the actual IVF-ET outcome. This model reached the highest diagnostic efficiency (sensitivity 88.9%, specificity 75%, Youden index 0.639) at a diagnostic cut-off value of ≥ 0.360. CONCLUSIONS: The predictive model based on endometrial receptivity evaluations by 3D ultrasound had high diagnostic efficiency and could be a simple and effective tool to predict first-trimester pregnancy inception after IVF-ET.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Infertilidad Femenina
Tipo de estudio:
Diagnostic_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Límite:
Female
/
Humans
/
Pregnancy
Idioma:
En
Revista:
BMC Med Imaging
Asunto de la revista:
DIAGNOSTICO POR IMAGEM
Año:
2022
Tipo del documento:
Article
País de afiliación:
China
Pais de publicación:
Reino Unido