Oxygen reserve index guided fraction of inspired oxygen titration to reduce hyperoxemia during laparoscopic gastrectomy: A randomized controlled trial.
Ahn, Jin Hee; Shim, Jae-Geum; Park, Jiyeon; Lee, Sung Hyun; Ryu, Kyoung-Ho; Cho, Eun-Ah.
Afiliación
  • Ahn JH; Department of Anaesthesiology and Pain Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
Medicine (Baltimore) ; 101(46): e31592, 2022 Nov 18.
Article en En | MEDLINE | ID: mdl-36401493
BACKGROUND: The usefulness of the oxygen reserve index (ORi) in reducing hyperoxemia remains unclear. We designed this study to investigate whether fraction of inspired oxygen (FiO2) adjustment under a combination of ORi and peripheral oxygen saturation (SpO2) guidance can reduce intraoperative hyperoxemia compared to SpO2 alone. METHODS: In this prospective, double-blind, randomized controlled study, we allocated patients scheduled for laparoscopic gastrectomy to the SpO2 group (FiO2 adjusted to target SpO2 ≥ 98%) or the ORi-SpO2 group (FiO2 adjusted to target 0 < 0 ORi < .3 and SpO2 ≥ 98%). The ORi, SpO2, FiO2, arterial partial pressure of oxygen (PaO2), and incidence of severe hyperoxemia (PaO2 ≥ 200 mm Hg) were recorded before and 1, 2, and 3 hours after surgical incision. Data from 32 and 30 subjects in the SpO2 and ORi-SpO2 groups, respectively, were analyzed. RESULTS: PaO2 was higher in the SpO2 group (250.31 ± 57.39 mm Hg) than in the ORi-SpO2 group (170.07 ± 49.39 mm Hg) 1 hour after incision (P < .001). PaO2 was consistently higher in the SpO2 group than in the ORi-SpO2 group, over time (P = .045). The incidence of severe hyperoxemia was higher in the SpO2 group (84.4%) than in the ORi-SpO2 group (16.7%, P < .001) 1 hour after incision. Higher FiO2 was administered to the SpO2 group [52.5 (50-60)] than the ORi-SpO2 group [40 (35-50), P < .001] 1 hour after incision. SpO2 was not different between the 2 groups. CONCLUSION: The combination of ORi and SpO2 guided FiO2 adjustment reduced hyperoxemia compared to SpO2 alone during laparoscopic gastrectomy.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Oxígeno / Laparoscopía Tipo de estudio: Clinical_trials / Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Medicine (Baltimore) Año: 2022 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Oxígeno / Laparoscopía Tipo de estudio: Clinical_trials / Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Medicine (Baltimore) Año: 2022 Tipo del documento: Article Pais de publicación: Estados Unidos