Your browser doesn't support javascript.
loading
HOMA-IR and HOMA2-IR estimation based on glycated hemoglobin as an alternative for fasting glucose.
Delanghe, Joris R; Verlinde, Evelyn; Speeckaert, Marijn M; Maenhout, Thomas.
Afiliación
  • Delanghe JR; Department of Clinical Chemistry, Ghent University Hospital, Ghent, Belgium.
  • Verlinde E; Leadlife, Ghent, Belgium.
  • Speeckaert MM; Department of Internal Medicine, Ghent University Hospital, Ghent, Belgium.
  • Maenhout T; Research Foundation-Flanders (FWO), Brussels, Belgium.
Acta Clin Belg ; 78(4): 308-312, 2023 Aug.
Article en En | MEDLINE | ID: mdl-36573787
BACKGROUND: Diabetes mellitus is a major global public health problem. Homeostatic Model Assessment for Insulin Resistance (HOMA-IR) is a key laboratory index in the assessment of insulin resistance. The calculation of HOMA-IR and its updated version HOMA2-IR are partly based on plasma glucose determinations, which are prone to important pre-analytical errors. As glycated hemoglobin (Hb) fractions strongly correlate with fasting glucose levels and are more stable analytes, we explored the possibilities of using glycated Hb fractions for calculating HOMA-IR. METHODS: Labile Hb and HbA1c fractions were simultaneously assayed on a Tosoh G8 analyzer and expressed as %. Fasting glucose was measured in fluoride plasma using a hexokinase method. A Lumipulse G1200 luminescence immunoassay was used to measure serum insulin. The HOMA-IR and HOMA2-IR values were compared to corresponding indices calculated using glucose and glycated Hb fractions. RESULTS: Labile Hb could be measured with between-run CVs of 2.2-2.3%. Labile Hb correlated with both glycemia (r = 0.80) and HbA1c results (r = 0.73). HbA1c-derived estimated average glucose (eAG)-based HOMA calculation correlated very well with HOMA-IR (r2 = 0.9972). Based on eAG calculations, HOMA2-IR (%B, %S, and IR) gave comparable results, as compared to labile Hb-based calculations, in particular for fasting plasma glucose values between 4.44 and 6.67 mmol/L. CONCLUSIONS: HbA1c and eAG are practical alternatives for glucose for estimating HOMA-IR. The use of glycated Hb enables home sampling for HOMA-IR and HOMA2-IR calculation.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Resistencia a la Insulina / Diabetes Mellitus Tipo 2 Límite: Humans Idioma: En Revista: Acta Clin Belg Año: 2023 Tipo del documento: Article País de afiliación: Bélgica Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Resistencia a la Insulina / Diabetes Mellitus Tipo 2 Límite: Humans Idioma: En Revista: Acta Clin Belg Año: 2023 Tipo del documento: Article País de afiliación: Bélgica Pais de publicación: Reino Unido