Your browser doesn't support javascript.
loading
Uterine artery embolization for postpartum hemorrhage with placenta accreta spectrum.
Jeon, Go Un; Jeon, Gyeong Sik; Kim, Young Ran; Ahn, Eun Hee; Jung, Sang Hee.
Afiliación
  • Jeon GU; Department of Radiology, CHA Bundang Medical Center, CHA University School of Medicine, Seongnam, Republic of Korea.
  • Jeon GS; Department of Radiology, CHA Bundang Medical Center, CHA University School of Medicine, Seongnam, Republic of Korea.
  • Kim YR; Department of Obstetrics and Gynecology, CHA Bundang Medical Center, CHA University School of Medicine, Seongnam, Republic of Korea.
  • Ahn EH; Department of Obstetrics and Gynecology, CHA Bundang Medical Center, CHA University School of Medicine, Seongnam, Republic of Korea.
  • Jung SH; Department of Obstetrics and Gynecology, CHA Bundang Medical Center, CHA University School of Medicine, Seongnam, Republic of Korea.
Acta Radiol ; 64(7): 2321-2326, 2023 Jul.
Article en En | MEDLINE | ID: mdl-37093745
BACKGROUND: The reported success rate of uterine artery embolization (UAE) for postpartum hemorrhage (PPH) differs by the cause of bleeding; in some reports, UAE shows less successful results in patients with placenta accreta spectrum (PAS). PURPOSE: To evaluate the outcome of UAE for treating PPH associated with PAS. MATERIAL AND METHODS: From September 2011 to September 2021, 227 patients (mean age = 34.67±4.06 years; age range = 19-47 years) underwent UAE for managing intractable PPH. Patients were divided into two groups: those with PAS (n = 46) and those without PAS (n = 181). Delivery details, embolization details, and procedure-related outcomes were compared between the two groups. P values <0.05 were considered statistically significant. RESULTS: The technical success rate was 96.9% (n = 222) and the clinical success rate was 93.8% (n = 215). There were no significant differences in outcome of UAE between the two patient groups. The technical success rate was 95.7% (n = 44) in patients with PAS and 98.3% (n = 178) in patients without PAS (P = 0.267). The clinical success rate was 91.3% (n = 42) in patients with PAS and 95.6% (n = 173) in patients without PAS (P = 0.269). There were 24 cases of immediate complications, including pelvic pain (n = 20), urticaria (n = 3), and puncture site hematoma (n = 1). No major complication was reported. CONCLUSION: UAE is a safe and effective method to control intractable PPH for patients with or without PAS.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Placenta Accreta / Embolización de la Arteria Uterina / Hemorragia Posparto Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Adult / Female / Humans / Middle aged / Pregnancy Idioma: En Revista: Acta Radiol Año: 2023 Tipo del documento: Article Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Placenta Accreta / Embolización de la Arteria Uterina / Hemorragia Posparto Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Adult / Female / Humans / Middle aged / Pregnancy Idioma: En Revista: Acta Radiol Año: 2023 Tipo del documento: Article Pais de publicación: Reino Unido