Your browser doesn't support javascript.
loading
High-resolution three-dimensional dosimetry in clinically relevant volumes utilizing optically stimulated luminescence.
Jensen, Mads L; Julsgaard, Brian; Turtos, Rosana M; Skyt, Peter S; Jensen, Morten B; Muren, Ludvig P; Balling, Peter.
Afiliación
  • Jensen ML; Department of Physics and Astronomy, Aarhus University, Aarhus, Denmark.
  • Julsgaard B; Department of Physics and Astronomy, Aarhus University, Aarhus, Denmark.
  • Turtos RM; Interdisciplinary Nanoscience Center, Aarhus University, Aarhus, Denmark.
  • Skyt PS; Department of Physics and Astronomy, Aarhus University, Aarhus, Denmark.
  • Jensen MB; Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.
  • Muren LP; Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.
  • Balling P; Department of Medical Physics, Aarhus University Hospital, Aarhus, Denmark.
Med Phys ; 51(3): 2200-2209, 2024 Mar.
Article en En | MEDLINE | ID: mdl-37929802
ABSTRACT

BACKGROUND:

The continued development of new radiotherapy techniques requires dosimetry systems that satisfy increasingly rigorous requirements, such as high sensitivity, wide dose range, and high spatial resolution. An emerging requirement is the ability to read out doses in three dimensions (3D) with high precision and spatial resolution. A few dosimetry systems with 3D capabilities are available, but their application in a clinical workflow is limited for various reasons, primarily originating from their chemical nature. The search for a 3D dosimetry system with potential for clinical implementation is thus ongoing.

PURPOSE:

To demonstrate the capabilities of a novel optically-stimulated-luminescence (OSL)-based 3D dosimetry system capable of measuring radiation doses in clinically relevant volumes.

METHODS:

A laser-based readout system was used to measure dose distributions delivered by both photons and protons, utilizing the OSL from a 50 × 50 × 50 $50\times 50\times 50$  mm 3 $^3$ YSOCe crystal. A homogeneous treatment plan consisting of two opposing photon fields was used to establish an inhomogeneity correction map of the crystal response and demonstrated the accuracy and precision of the system. The crystal was additionally irradiated with a photon treatment plan consisting of three overlapping 10 × 10 $10\times 10$  mm 2 $^2$ fields delivered from different angles, and a proton treatment plan consisting of four pencil beams with energies 90 MeV ( × 2 $\times 2$ ), 115 MeV, and 140 MeV. The system abilities were quantified by comparing the 3D-resolved measurements to Monte Carlo simulations.

RESULTS:

The dose map reproducibility of the system was found to be within 2% including both statistical and systematic errors. The measurements yielded integrated doses from a volume of 50 × 50 × 40 $50\times 50\times 40$  mm 3 $^3$ with voxel volumes of just 0.28 × 0.28 × 0.50 $0.28\times 0.28\times 0.50$  mm 3 $^3$ . An excellent agreement between the 3D-resolved measurements and the simulations was found for both photon- and proton-irradiation.

CONCLUSIONS:

The capabilities of the devised system for measuring clinically relevant fields of photons and proton pencil beams within a clinically relevant volume were demonstrated. The system poses as a promising candidate for clinical applications, and enables future research in the field of OSL-based tissue-equivalent 3D dosimetry.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Luminiscencia / Dosimetría con Luminiscencia Ópticamente Estimulada Idioma: En Revista: Med Phys Año: 2024 Tipo del documento: Article País de afiliación: Dinamarca

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Luminiscencia / Dosimetría con Luminiscencia Ópticamente Estimulada Idioma: En Revista: Med Phys Año: 2024 Tipo del documento: Article País de afiliación: Dinamarca