Your browser doesn't support javascript.
loading
Reconstruction of Angstrom resolution exit-waves by the application of drift-corrected phase-shifting off-axis electron holography.
Lindner, J; Ross, U; Meyer, T; Boureau, V; Seibt, M; Jooss, Ch.
Afiliación
  • Lindner J; Institute of Materials Physics, University of Goettingen, Friedrich-Hund-Platz 1, 37077, Goettingen, Germany.
  • Ross U; 4th Institute of Physics - Solids and Nanostructures, University of Goettingen, Friedrich-Hund-Platz 1, 37077, Goettingen, Germany.
  • Meyer T; Institute of Materials Physics, University of Goettingen, Friedrich-Hund-Platz 1, 37077, Goettingen, Germany.
  • Boureau V; Interdisciplinary Center for Electron Microscopy, École Polytechnique Fédérale de Lausanne, CH-1015, Lausanne, Switzerland.
  • Seibt M; 4th Institute of Physics - Solids and Nanostructures, University of Goettingen, Friedrich-Hund-Platz 1, 37077, Goettingen, Germany.
  • Jooss C; Institute of Materials Physics, University of Goettingen, Friedrich-Hund-Platz 1, 37077, Goettingen, Germany; International Center for Advanced Studies of Energy Conversion (ICASEC), University of Goettingen, D-37077, Goettingen, Germany. Electronic address: cjooss@gwdg.de.
Ultramicroscopy ; 256: 113880, 2024 Feb.
Article en En | MEDLINE | ID: mdl-37952372
ABSTRACT
Phase-shifting electron holography is an excellent method to reveal electron wave phase information with very high phase sensitivity over a large range of spatial frequencies. It circumvents the limiting trade-off between fringe spacing and visibility of standard off-axis holography. Previous implementations have been limited by the independent drift of biprism and sample. We demonstrate here an advanced drift correction scheme for the hologram series that exploits the presence of an interface of the TEM specimen to the vacuum area in the hologram. It allows to obtain reliable phase information up to 2π/452 at the 1 Å information limit of the Titan 80-300 kV environmental transmission electron microscope used, by applying a moderate voltage of 250 V to a single biprism for a fringe spacing of 1 Å. The obtained phase and amplitude information is validated at a thin Pt sample by use of multislice image simulation with the frozen lattice approximation and shows excellent agreement. The presented method is applicable in any TEM equipped with at least one electron biprism and thus enables achieving high resolution off-axis holography in various instruments including those for in-situ applications. A software implementation for the acquisition, calibration and reconstruction is provided.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Ultramicroscopy Año: 2024 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Ultramicroscopy Año: 2024 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Países Bajos