Your browser doesn't support javascript.
loading
Detecting EGFR gene amplification using a fluorescence in situ hybridization platform based on digital microfluidics.
Shen, Chuanjie; Zhan, Cheng; Tong, Zhaoduo; Yin, Hao; Hui, Jianan; Qiu, Shihui; Li, Qiushi; Xu, Xin; Ma, Hui; Wu, Zhenhua; Shi, Nan; Mao, Hongju.
Afiliación
  • Shen C; State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China; Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China.
  • Zhan C; Department of Thoracic Surgery, Zhongshan Hospital, Fudan University, Shanghai, 200030, China.
  • Tong Z; State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China; Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China.
  • Yin H; State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China; Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China.
  • Hui J; State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China.
  • Qiu S; State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China; Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China.
  • Li Q; State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China.
  • Xu X; State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China.
  • Ma H; State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China.
  • Wu Z; State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China; Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China.
  • Shi N; Suzhou Inst Nanotech & Nanob, Chinese Academy of Sciences, Suzhou, 215123, China. Electronic address: nshi2021@sinano.ac.cn.
  • Mao H; State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China; Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China. Electroni
Talanta ; 269: 125444, 2024 Mar 01.
Article en En | MEDLINE | ID: mdl-38042143
Signal transduction mediated by epidermal growth factor receptor (EGFR) gene affects the proliferation, invasion, metastasis, and angiogenesis of tumor cells. In particular, non-small cell lung cancer (NSCLC) patients with increased in copy number of EGFR gene are often sensitive to tyrosine kinase inhibitors. Despite being the standard for detecting EGFR amplification in the clinic, fluorescence in situ hybridization (FISH) traditionally involves repetitive and complex benchtop procedures that are not only time consuming but also require well-trained personnel. To address these limitations, we develop a digital microfluidics-based FISH platform (DMF-FISH) that automatically implements FISH operations. This system mainly consists of a DMF chip for reagent operation, a heating array for temperature control and a signal processing system. With the capability of automatic droplet handling and efficient temperature control, DMF-FISH performs cell digestion, gradient elution, hybridization and DAPI staining without manual intervention. In addition to operational feasibility, DMF-FISH yields comparable performance with the benchtop FISH protocol but reducing the consumption of DNA probe by 87 % when tested with cell lines and clinical samples. These results highlight unique advantages of the fully automated DMF-FISH system and thus suggest its great potential for clinical diagnosis and personalized therapy of NSCLC.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Carcinoma de Pulmón de Células no Pequeñas / Neoplasias Pulmonares Límite: Humans Idioma: En Revista: Talanta Año: 2024 Tipo del documento: Article País de afiliación: China Pais de publicación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Carcinoma de Pulmón de Células no Pequeñas / Neoplasias Pulmonares Límite: Humans Idioma: En Revista: Talanta Año: 2024 Tipo del documento: Article País de afiliación: China Pais de publicación: Países Bajos